Place of Origin: | China |
Brand Name: | Diacegene |
Certification: | CE |
Model Number: | β-HCG |
Minimum Order Quantity: | 1000 |
---|---|
Packaging Details: | 25 Test/carton |
Delivery Time: | 10~15 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 10,000 pcs/week |
Test Range: | 2.0~200000 MIU/mL | Valid Period: | 15 Months |
---|---|---|---|
Reaction Time: | 4~12 Minutes | Package: | 25 Tests |
Storage: | 2~8°C | Sample Type: | Serum/Plasma/Whole Blood |
Methodology: | Immunofluorescence | Sample Size: | 150μl~250μl |
High Light: | 25pcs Hormone Test Kits,Hcg At Home Hormone Test Kits,Serum hcg hormone check kit |
Wide Test Range Quantitative β-HCG Analysis for pregnant women
Intended use:
In-vitro quantitative determination of the concentration of β-HCG in human serum, human plasma, and human whole blood samples is clinically mainly used for auxiliary diagnosis of ectopic pregnancy and early pregnancy.
Summary:
Serum HCG is a commonly used indicator for the diagnosis of early pregnancy, and it is also used for early detection and differential diagnosis of abnormal pregnancy diseases. Elevated serum HCG is common in women of childbearing age. After a normal conception, the HCG content in the blood increased rapidly, reaching the highest peak at 60-80 days of gestation, and then gradually decreased, reaching the lowest point at 160-180 days of gestation, but it was still significantly higher than normal, and then it rose slightly and continued until delivery; both During fetal pregnancy, serum HCG is more than doubled than single pregnancy, and during ectopic pregnancy, serum HCG is lower than the normal pregnancy value during the same period. Detection methods include chemiluminescence, colloidal gold, immunochromatography, enzyme-linked immunoassay, etc.
Storage and stability:
The test card and buffer are stored at 2℃~8℃ for 15 months. The aluminum foil bag of the test card should be used within 2 hours after it is opened. Transportation and storage should be carried out under the conditions of 2℃~8℃.
Applicable instrument:
The models of Auto-HFIAS 1000 and HFD-Station produced by Sichuan New Health Biotech Co., Ltd. are dry fluorescence immunoassay analyzers.
Parameter:
Item | Sample Type | Sample Size | Reaction Time | Storage |
---|---|---|---|---|
Parameter | Serum/Plasma/Whole blood | 150μl~250μl | 4-12 Minutes | 2~8°C |
Contact Person: Eric King
Tel: +8613612761334
Oropharyngeal 5pcs Covid 19 Rapid Test Kit ISO13485 Approval
Nasopharynx IVD Flu Test Kit , 5 Or 25 Or 50 Pcs/Box COVID-19 Ag Card
At Home 8 Minutes POCT Covid 19 Rapid Test Kit For IgG IgM
Multi Pack IVD Covid 19 Rapid Test Kit 18 Months Validity For Blood
Rapid Poct Chemistry Analyzer , 3-15 Minutes Hormone Analysis Machine
Fluorescent Immunochemistry Analyzer , Small Poct Analyser
POCT Analyzer Hormones Analyzer Immuno Fluorescence Immunoassay Analyzer
Small Poct Hormone Analyzer , 4-8mins Point Of Care Blood Analyzer
8mins Hs CTnI Cardiac Marker Test Kit Homogeneous Fluorescent Dynamic Assay
200ul Cardiac Marker Test Kit 10mg / L Immunofluorescence D Dimer
0.1mg / L Cardiac Marker Test Kit Immunofluorescence D Dimer 5minutes
Rapid POCT Cardiac Marker Test Kit D Dimer Immunofluorescence 5 Minutes Speed