Place of Origin: | Chengdu,China |
Brand Name: | Diacegene,Xincheng Bio |
Certification: | CE,ISO13485,ISO9001 |
Model Number: | IFP series |
Minimum Order Quantity: | 100 tests |
---|---|
Price: | Negotiable |
Packaging Details: | 25 tests/box |
Delivery Time: | 3-25 work days |
Payment Terms: | T/T, D/A, D/P, Western Union, L/C, MoneyGram |
Supply Ability: | 100,000 tests/week |
Method: | Dry Immunofluorescence | Test Speed: | 15 Minutes |
---|---|---|---|
Certificate: | CE | Name: | CTnI+Myo+CK-MB |
Usage: | Professional Use | Package: | 25 Tests/box |
Net Weight: | 0.4 Kgs | Shelf Life: | 24 Months |
High Light: | 400ul Cardiac Marker Test Kit,Cardiac Marker 0.4 kgs Test Kit,CK MB Immunofluorescence Cardiac Test Kit |
400ul Cardiac Marker Test Kit CTnI Myo CK-MB Immunofluorescence
Cat. No.:
Cat. No.: | Specification | Test Card (strip) |
Buffer (Loading Quantity × Bottles) |
Id chip (Optional) |
T2601A | 25 tests | 25 | 400μl×25 | 1 |
T2602A | 50 tests | 50 | 400μl×50 | 1 |
T2603A | 100 tests | 100 | 400μl×100 | 1 |
Note: Applicable to IFP-2000 produced by Xincheng Bio.The packaging specification of the model is equipped with id chip. |
Intended use
In vitro quantitative determination of the concentrations of myoglobin, creatine kinase isoenzyme, and troponin I in human serum, human plasma, and human whole blood samples.
Reagents components
The kit consists of a test card, buffer, and id chip (optional). among them:
Test card: Consists of a reagent strip and a plastic box. The main components of the reagent strip are: nitrocellulose membrane, absorbent paper, PVC board and labeling pad; the reagent strip is coated with mouse anti-human MYO monoclonal antibody (each reagent strip contains 0.20μg~1.20μg), Mouse anti-human CK-MB monoclonal antibody (containing 0.08μg~0.80μg on the reagent strip per person), mouse anti-human cTnI monoclonal antibody (containing 0.08μg~0.80μg on the reagent strip per person) and anti-rabbit IgG ( Each reagent strip contains 0.20μg~1.50μg), fluorescently labeled mouse anti-human MYO monoclonal antibody (each reagent strip contains 0.06μg~0.22μg), mouse anti-human CK-MB monoclonal antibody (each person Each kit contains 0.06μg~0.22μg), mouse anti-human cTnI monoclonal antibody (each kit contains 0.06μg~0.34μg), fluorescently labeled rabbit IgG (each kit contains 0.20μg~1.50 μg).
Buffer: Tris buffer (Tris) (50mmol/L).
Id chip: Contains basic project information, batch information and calibration curve.
The measurement system can be traced to the MYO,CK-MB and cTnI measurement system approved by NMPA.
The components in the kits with different batch numbers cannot be interchanged or mixed.
Compatiable instrument:
Contact Person: Sindy Sue
Tel: +8618980880608
Oropharyngeal 5pcs Covid 19 Rapid Test Kit ISO13485 Approval
Nasopharynx IVD Flu Test Kit , 5 Or 25 Or 50 Pcs/Box COVID-19 Ag Card
At Home 8 Minutes POCT Covid 19 Rapid Test Kit For IgG IgM
Multi Pack IVD Covid 19 Rapid Test Kit 18 Months Validity For Blood
Rapid Poct Chemistry Analyzer , 3-15 Minutes Hormone Analysis Machine
Fluorescent Immunochemistry Analyzer , Small Poct Analyser
POCT Analyzer Hormones Analyzer Immuno Fluorescence Immunoassay Analyzer
Small Poct Hormone Analyzer , 4-8mins Point Of Care Blood Analyzer
8mins Hs CTnI Cardiac Marker Test Kit Homogeneous Fluorescent Dynamic Assay
200ul Cardiac Marker Test Kit 10mg / L Immunofluorescence D Dimer
0.1mg / L Cardiac Marker Test Kit Immunofluorescence D Dimer 5minutes
Rapid POCT Cardiac Marker Test Kit D Dimer Immunofluorescence 5 Minutes Speed