Place of Origin: | China |
Brand Name: | Diacegene |
Certification: | CE |
Model Number: | SARS-CoV-2 Antibody |
Minimum Order Quantity: | 1000 |
---|---|
Packaging Details: | 25test/carton |
Delivery Time: | 10~15 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 10,000 pcs/week |
Sample Type: | Serum/Plasma/Whole Blood | Valid Period: | 15 Months |
---|---|---|---|
Storage: | 2~30°C | Methodology: | Immunofluorescence |
Reaction Time: | 8 Minutes | Package: | 25 Tests |
Test Environment: | Room Temperature | Sample Size: | 150μl~250μl |
High Light: | POCT igg igm rapid test,igg igm immunofluorescence method,COVID-19 immunofluorescence method |
Immunofluorescent Method for POCT with COVID-19 IgG, IgM Antibody Rapid Test Kit
Reagents Components:
The reagent consists of test cards, tips, and instructions. Wherein:
Test card: It consists of a reagent strip and plastic box. The main ingredients on the reagent strip are: nitrocellulose membrane, absorbent paper, PVC board and other test strip support; the reagent strip is coated with goat anti-human IgM/G antibody (each reagent strip contains 0.11 μg to 1.12 μg) and goat anti-rabbit IgG (each reagent strip contains 0.20 μg to 1.50 μg).
The determination system can be traced to the measurement procedure selected by the manufacturer;
The ingredients in the kits of different batches cannot be interchanged or mixed.
Storage and stability:
The test card is valid for 15 months at 2 ℃ to 30 ℃. Transport and storage should be carried out at 2 ℃ to 30 ℃.
Specimen collection and preparation:
1. Human whole blood (heparin anticoagulation recommended), serum, or plasma (heparin anticoagulation recommended) sample.
2. Test the sample as soon as possible after it is collected. If it cannot be measured in time, it should be transported and stored as required.
3. The samples should be transported and stored at 2℃ to 8℃. Whole blood samples can be stored for 7 days at 2℃ to 8℃, and serum/plasma samples can be stored for 3 days at 2℃ to 8℃. Stable at -20 ℃ for 7 days. Refrigerated samples must be left to recover from 20℃ to 28℃ before testing,multiple freeze-thaw cycles should be avoided. The sample should be measured during the stable period, otherwise, the sample must be collected again.
4. The test result may be affected by severe jaundice, hemolysis, and lipemia samples.
Parameter:
Item | Reaction Time | Valid period | RSample Type | Storage |
---|---|---|---|---|
Parameter | 8 Minutes | 15 Months | Serum/Plasma/Whole blood | 2~30°C |
Contact Person: Eric King
Tel: +8613612761334
Oropharyngeal 5pcs Covid 19 Rapid Test Kit ISO13485 Approval
Nasopharynx IVD Flu Test Kit , 5 Or 25 Or 50 Pcs/Box COVID-19 Ag Card
At Home 8 Minutes POCT Covid 19 Rapid Test Kit For IgG IgM
Multi Pack IVD Covid 19 Rapid Test Kit 18 Months Validity For Blood
Rapid Poct Chemistry Analyzer , 3-15 Minutes Hormone Analysis Machine
Fluorescent Immunochemistry Analyzer , Small Poct Analyser
POCT Analyzer Hormones Analyzer Immuno Fluorescence Immunoassay Analyzer
Small Poct Hormone Analyzer , 4-8mins Point Of Care Blood Analyzer
8mins Hs CTnI Cardiac Marker Test Kit Homogeneous Fluorescent Dynamic Assay
200ul Cardiac Marker Test Kit 10mg / L Immunofluorescence D Dimer
0.1mg / L Cardiac Marker Test Kit Immunofluorescence D Dimer 5minutes
Rapid POCT Cardiac Marker Test Kit D Dimer Immunofluorescence 5 Minutes Speed