Home ProductsCovid 19 Rapid Test Kit

MDA Clinical Nasal Swab Covid 19 Antigen Test Kits With Latex Immunochromatography

MDA Clinical Nasal Swab Covid 19 Antigen Test Kits With Latex Immunochromatography

  • MDA Clinical Nasal Swab Covid 19 Antigen Test Kits With Latex Immunochromatography
  • MDA Clinical Nasal Swab Covid 19 Antigen Test Kits With Latex Immunochromatography
MDA Clinical Nasal Swab Covid 19 Antigen Test Kits With Latex Immunochromatography
Product Details:
Place of Origin: China
Brand Name: Diacegene
Certification: CE, ISO13485, ISO9001, FSC
Model Number: T4001W
Payment & Shipping Terms:
Minimum Order Quantity: 1000 tests
Packaging Details: 1test,5tests,25tests/package
Delivery Time: 3-10 days
Payment Terms: T/T, Western Union
Supply Ability: 500,000tests per week
Contact Now
Detailed Product Description
Method: Latex Immunochromatography Type: Nasal Swab
Storage Temperature: 2-30 ℃ Valid Time: 18 Months
Result Showing: Within 15-20minutes Clinical Sensitivity: 96.0%
Clinical Specificity: 100% Certificates: Malaysia MDA Approval
High Light:

MDA Clinical Antigen Test Kits

,

Nasal Swab Antigen Test Kits

,

Latex Immunochromatography Antigen Kits

Covid19 home test antigen kits nasal swab CE mark

 

 

Cat.No specifiation test card sample preservation solution dripper swab
T4001W
1 tests 1 400μL*1 1 1
T4002W
5 tests 5 400μL*5 5 5
T4003W
25 tests 25 400μL*25 25 25
 
Test procedure
1.Preparation
1.1 Remove the kit from the storage environment; freezing is prohibited.
1.2 Open the carton packaging and remove a set of test cards, sample preservation solution, droppers and swabs.
1.3 Return the remaining unused test kits to storage.
1.4 If removed from the refrigerator, allow to stand at room temperature for 30 minutes; otherwise skip this step.
2. Specimen collection:
2.1 Lift open the swab bag and remove the swab (nasal swab).
2.2 Insert the swab (nasal swab) into the nasal cavity 1.5 cm deep.
2.3 Swab the mucosa of the nostril 5 times to ensure that both mucus and cells are collected.
2.4 Repeat steps 2.2-2.3 in the other nostril using this swab.
3. Sample extraction
3.1 Puncture the aluminum foil of the sample
preservation tube with the dropper, and then set the dropper aside.
3.2 Immerse the swabbed sample preserving tube in the liquid after sampling. Stir 10-20 times close to the inner wall of the tube and gently shake the tube up and
down 2-3 times to dissolve the sample in the sample preservation fluid.
3.3 Squeeze the swab against the wall of the tube, keeping it close to the wall of the tube to remove the swab so that the liquid remains in the tube as much as
possible.
3.4 Insert the dropper into the sample preservation tube again.
4. Detection
4.1 Tear the aluminum foil bag, take out the test card and lay it flat.
4.2 Aspirate the sample reservoir containing the sample with a dropper and add 3-4 drops to the sample addition well of the test card.
4.3 Set the alarm clock and observe the results within 15-20 minutes, the results displayed after 30 minutes are invalid.
 
5. Result interpretation
The test results are of the following three kinds.
POSITIVE:
Two red lines appear. One red line appears in the control region(C), and one red line in the test region(T). The shade of color may vary,but it should be considered positive whenever there is even a faint line.
NEGATIVE:
Only one red line appears in the control region(C), and no line in the test region(T). The negative result indicates that there are no Novel coroinavirus particles in the sample or the number of viral particles is below the detectable range.
INVALID:
No red line appears in the control region(C). The test is invalid even if there is a line on test region(T).
 
MDA Clinical Nasal Swab Covid 19 Antigen Test Kits With Latex Immunochromatography 0
 

Contact Details
Sichuan Xincheng Biological Co., Ltd.

Contact Person: Poni Yin

Tel: +8615928809061

Send your inquiry directly to us
Best Products
Other Products