Place of Origin: | China |
Brand Name: | Diacegene |
Certification: | CE |
Model Number: | COVID-19 Rapid Self-test Kits |
Minimum Order Quantity: | 1000 |
---|---|
Price: | 0.8 to 1.5USD |
Packaging Details: | 1 Test/kit, 5 tests/kit. 25 tests/kit |
Delivery Time: | 10~15 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 10,000 pcs/week |
Time: | 15 Minutes To Get The Result | Clinical Sensitivity: | 96% |
---|---|---|---|
Clinical Specificity: | 100% | Total Compliance Rate: | 98% |
High Light: | SARS-Cov-2 Test Kit,COVID-19 diagnostic test kits,Antigen Self Test Kits |
Cat. No.: | Specification | Test card (Strip) | Sample Processing fluid (Vials) | SalivaCollector (Piece) |
T4001W | 1 Test | 1 | 1 | 1 |
T4002W | 5Tests | 5 | 5 | 5 |
T4003W | 25Tests | 25 |
25 |
25 |
Intended use
Intended use The product is used for the in vitro qualitative detection of SARS-Cov-2 N-protein antigen in human nasal swab
Summary
Intended use The product is used for the in vitro qualitative detection of SARS-Cov-2 N-protein antigen in human nasal swab
Test principle
Latex Immunochromatography method is used to detect SARS-Cov-2 antigens. After treatment when SARS-Cov-2 antigens in the sample are added to the detection hole, the antigen and latex labeled antibody (monoclonal antibody against SARS-Cov-2) form an immune complex. The complex moves with the liquid to the nitrocellulose membrane, and the detection area of the nitrocellulose membrane is coated with another one. When monoclonal antibody is against SARS-Cov-2 antigen, the immune complex is captured by the antibody on nitrocellulose membrane, forming a red reaction line: the result is positive. When the sample does not contain SARS-Cov-2 antigen or are lower than the minimum detection limit of this kit, no red reaction line appears in the detection area: the result is negative. At the same time, whether the result is positive or negative, as the internal control standard of reagents, a red reaction line will be formed in the quality control area (line C), which is used to judge whether the chromatographic process is normal or not.
Reagents components
The reagent consists of test card, sample preservation solution , dripper and swab. 1. The test card consists of reagent strip and plastic case. The main components of the test strip are: Latex labeled SARS-Cov-2 nucleoprotein monoclonal antibody; SARS-Cov-2 nucleoprotein monoclone antibody coatted in the detection area of nitrocellulose membrane; anti mouse immunoglobulin G polyclonal antibody fixed in the quality control area of nitrocellulose membrane. 2. The main preservation solution was phosphate buffer (PBS, 50mm, ph7.2).
Contact Person: Eric King
Tel: +8613612761334
Oropharyngeal 5pcs Covid 19 Rapid Test Kit ISO13485 Approval
Nasopharynx IVD Flu Test Kit , 5 Or 25 Or 50 Pcs/Box COVID-19 Ag Card
At Home 8 Minutes POCT Covid 19 Rapid Test Kit For IgG IgM
Multi Pack IVD Covid 19 Rapid Test Kit 18 Months Validity For Blood
Rapid Poct Chemistry Analyzer , 3-15 Minutes Hormone Analysis Machine
Fluorescent Immunochemistry Analyzer , Small Poct Analyser
POCT Analyzer Hormones Analyzer Immuno Fluorescence Immunoassay Analyzer
Small Poct Hormone Analyzer , 4-8mins Point Of Care Blood Analyzer
8mins Hs CTnI Cardiac Marker Test Kit Homogeneous Fluorescent Dynamic Assay
200ul Cardiac Marker Test Kit 10mg / L Immunofluorescence D Dimer
0.1mg / L Cardiac Marker Test Kit Immunofluorescence D Dimer 5minutes
Rapid POCT Cardiac Marker Test Kit D Dimer Immunofluorescence 5 Minutes Speed