Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent

Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent

  • Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent
  • Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent
  • Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent
Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent
Product Details:
Place of Origin: China
Brand Name: Diacegene
Certification: CE, ISO13485, ISO9001, FSC
Model Number: PCT
Payment & Shipping Terms:
Minimum Order Quantity: 100 tests
Price: $1-3
Packaging Details: 50test/100test per package
Delivery Time: 5-10 days
Payment Terms: L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability: 500000tests/month
Contact Now
Detailed Product Description
Instrument Classification: Class II After-sale Service: Online Technical Support
Function: Blood Analysis Usage: Vitro Diagnostic Reagent
Test Method: Chromatography Accuracy: 95%-98%
High Light:

Chromatography Procalcitonin Rapid Test Kit

,

98% Accuracy Procalcitonin Rapid Test Kit

,

POCT PCT Test Kit

PCT
Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent 0
High accuracy The Fine Quality PCT Immunofluorescence Method Test Kit
 
Storage and stability
The test card and buffer can be stored at 2℃~30℃ for 15 months, and the buffer solution can
be stored at 2℃~30℃ for 2h after opening the bottle . The aluminum foil bag of the test
card should be used within 2 hours after it is opened. Transportation and storage should be
carried out at 2℃~30℃.
 
Applicable instrument
The models produced by Sichuan Xincheng Biological Co., LTD:
IFP-2000, IFP-3000,Auto- HFIAS 1000, HFD-Station dry fluorescence immunoassay analyzer,
The models produced by Guangzhou Labsim Biotechnology Co., Ltd.:
AFS-1000, AFS2000A dry fluorescence immunoassay analyzer.
Specimen collection and preparation
1. Human serum, human plasma (EDTA anticoagulation), human whole blood (EDTA
anticoagulation) samples.
2. Serum/plasma should be separated or tested as soon as possible after sample collection to
avoid hemolysis. If it cannot be tested in time, it should be transported and stored as required.
3. The samples should be transported and stored at 2℃~8℃. Serum/plasma samples can be
stored at 2℃~8℃ for 7 days, stable for 1 month at -20℃ protected from light, whole blood
samples can be stored stable at 2℃~8℃ for 3 days, and the refrigerated samples must be
allowed to stand and restore to 20℃~28℃ before testing. The sample should be tested within
the stable period, otherwise the sample must be collected again.
4. Severe jaundice, hemolysis, and lipemia samples have a certain impact on the test results.
 
 
Parameters
Sample Type Whole Blood/Plasma/Serum
Sample Volume 75 μL
Assay Time 15 min
Working range 0.1-100ng/ml
Clinical Reference 0-0.5 ng/ml
Performance CV≤15%
Storage Temperature 2-30℃ (Room Temperature)
Shelf Life 18 months

 

 
Chromatography 98% Accuracy Procalcitonin Rapid Test Kit For Vitro Diagnostic Reagent 1