Glycosylated Hba1c Assay Kit , 15Mins Poct Blood Test CE Marked

Glycosylated Hba1c Assay Kit , 15Mins Poct Blood Test CE Marked

  • Glycosylated Hba1c Assay Kit , 15Mins Poct Blood Test CE Marked
Glycosylated Hba1c Assay Kit , 15Mins Poct Blood Test CE Marked
Product Details:
Place of Origin: China
Brand Name: Diacegene
Certification: CE, ISO13485, FSC
Model Number: HbA1c Assay kits
Payment & Shipping Terms:
Minimum Order Quantity: 1000tests
Price: USD3.0-USD4.5 test
Packaging Details: 50 tests 31 x 21 x 22 cm
Delivery Time: 3-5 Working Days
Payment Terms: T/T, Western Union, L/C
Supply Ability: 10,000 tests per day
Contact Now
Detailed Product Description
Package: 50 Per Box Certificate: CE Marked, FSC, ISO
Name: HbA1c Assay Kits Method: Immunofluorescence Chromatography
Size: 31 X 21 X 22 Cm Total Weight: 1.3 Kg
Accurate: More Than 95% Time: 15 Mins
High Light:

Glycosylated hba1c assay kit

,

hba1c poct blood test

,

15Mins poct blood test

 

Glycosylated hemoglobin A1c (HbA1c)assay kit (immunofluorescence chromatography)

 

Features

 

1. Test result shows in just 8-10 minutes.

2. Independent clinical trials show precision of more than 95%.

3. No lab setting is required for operation.

4. The cost is much less than nucleic acid test (PCR) with expensive labs.

 
Sample requirements
1. Human whole blood samples (heparin anticoagulation recommended).
2. Samples should be tested as soon as possible after collection to avoid hemolysis. If it is not measured in time, it should be transported and stored as required.
3. The samples should be transported and stored at 2 ℃~ 8 ℃. The whole blood samples can be kept stable for 2 days at 2 ℃~ 8 ℃. The frozen samples should be kept at 20 ℃~ 28 ℃ before testing. The samples should be determined within the stable period, otherwise the samples should be collected again.
4. Severe jaundice, hemolysis and lipid blood samples have certain influence on the test results.
 

Testing method
The reagent should be recovered to room temperature before testing, and the detection process should also be carried out at room temperature.
Inspection steps
1.1 open the kit and insert the test card into the import and export of the instrument.
1.2 150 μ l-250 μ l whole blood was added into the sample hole of the test card.
1.3 select the appropriate sample type in the instrument operation interface for testing.
1.4 after the test is completed, the test card shall be taken out from the instrument and processed according to the regulations.

2. Calculation The multi-point nonlinear/semi-logarithmic calibration mode was used, and the spline function was used as the calculation mode. The dose / corresponding curve was made according to the calibration value and absorbance change value. The concentration of HbA1c in the sample could be calculated on the dose / corresponding curve according to the absorbance change value.

3. Quality control It is suggested to use the quality control products sold in the market for indoor quality control, and judge whether it is under control or out of control according to the quality control rules. If it is out of control, please take appropriate corrective measures.

4. Calibration steps It is suggested that the new batch of reagents should be calibrated before the first use, and the calibration test
should be carried out regularly. When testing, put the calibrator into the sample position and select the corresponding calibration procedure in the instrument for calibration.

 

catogory test linear range time
others HbA1c 4%-14% 4/8mins

 