Place of Origin: | China |
Brand Name: | Diacegene |
Certification: | ISO13485 |
Model Number: | SARS-CoV-2 Antigen Test |
Minimum Order Quantity: | 20,000 |
---|---|
Price: | USD 2.5-USD 3.5 per test |
Delivery Time: | 3-15 business day |
Payment Terms: | T/T |
Specification: | 5 Tests/box | Methodology: | Latex Immunochromatography |
---|---|---|---|
Components: | Test Card, Dilution, Capillary Tube, Swab | Storage: | Room Temperature Or Refrigerated (2-30℃) |
Validity: | 18 Months | Sample Type: | Nasopharynx/oropharyngeal Swab Collection |
Instrument: | None | Device Type: | IVD (In Vitro Diagnostic) Medical Device |
Highlight: | Nasal Saliva Rapid Test Kit,IVD Saliva Rapid Test Kit |
SARS-Cov-2 Antigen Assay Kit by Latex Immunochromatography Method Self-Testing Type
5 Tests Per Boxes, Great for Family Members
Summary
This product can be used as a supplementary test indicator for suspected cases with negative nucleic acid test of SARS-Cov-2 or used in conjunction with nucleic acid testing in the diagnosis of suspected cases. It cannot be used as a basis for the diagnosis and exclusion of pneumonia caused by SARS-Cov-2 infection.
Storage and stability
When the Sars-Cov-2 antigen rapid detection kit is placed at room temperature or refrigerated (2-30 ℃), the validity period of the product is 18 months. Don't freeze.
Precautions and warnings
1. This product is for in vitro diagnostic only.
2. Please test in a quiet and independent scene such as home or hotel.
3. This product contains small parts, storage and testing process should avoid contact with infants and children.
4. Perform test at room temperature 15 to 30°C.
5. Ensure foil pouch containing test device is not damaged before opening for use.
6. Do not use after the expiration date.
7. Test cards, swabs, pipettes, etc. are for single use.
8. Wear gloves when handling samples to avoid contact with the reagent membrane and the sample (observation) area.
9. Do not mix components with different batches or different brands of in vitro diagnostic reagents.
10. To obtain accurate results, do not use samples that are too viscous or bloody. 11.Process in accordance with the Specimen collection and Sample extraction methods in this manual. Failure to follow the instructions for use may result in inaccurate test results.
Materials required but not provided
1. Timer (or stopwatch, clock)
2. Protective gloves
Interfering substances
When hemoglobin ≤ 5g/L, bilirubin ≤ 342.0 μmol/L, triglyceride ≤ 11.3mmol/L, rheumatoid factor ≤ 80IU/ml, there was no significant effect on the test results.
Sample Type | Nasopharynx/oropharyngeal swab collection |
Device Type | IVD (In vitro diagnostic) Medical Device |
Specification | 1or 5 or 25 tests/box |
Contact Person: Harvey Huang
Tel: +8615828328497
Oropharyngeal 5pcs Covid 19 Rapid Test Kit ISO13485 Approval
Nasopharynx IVD COV-2 Assay Kit , 5 Or 25 Or 50 Pcs/Box COVID-19 Ag Card
At Home 8 Minutes POCT Covid 19 Rapid Test Kit For IgG IgM
Multi Pack IVD Covid 19 Rapid Test Kit 18 Months Validity For Blood
Rapid Poct Chemistry Analyzer , 3-15 Minutes Hormone Analysis Machine
Fluorescent Immunochemistry Analyzer , Small Poct Analyser
POCT Analyzer Hormones Analyzer Immuno Fluorescence Immunoassay Analyzer
Small Poct Hormone Analyzer , 4-8mins Point Of Care Blood Analyzer
8mins Hs CTnI Cardiac Marker Test Kit Homogeneous Fluorescent Dynamic Assay
200ul Cardiac Marker Test Kit 10mg / L Immunofluorescence D Dimer
0.1mg / L Cardiac Marker Test Kit Immunofluorescence D Dimer 5minutes
Rapid POCT Cardiac Marker Test Kit D Dimer Immunofluorescence 5 Minutes Speed