Home ProductsSaliva Antigen Rapid Test Kit

Covid 19 Saliva Antigen Rapid Test Kit Sars-Cov-2 Saliva Swab Kit

Covid 19 Saliva Antigen Rapid Test Kit Sars-Cov-2 Saliva Swab Kit

  • Covid 19 Saliva Antigen Rapid Test Kit Sars-Cov-2 Saliva Swab Kit
Covid 19 Saliva Antigen Rapid Test Kit Sars-Cov-2 Saliva Swab Kit
Product Details:
Place of Origin: China
Brand Name: Diacegene
Certification: CE, ISO13485, ISO9001, FSC
Model Number: T4101W
Payment & Shipping Terms:
Minimum Order Quantity: 1000 tests
Packaging Details: 1test,5tests,25tests/package
Delivery Time: 3-10 days
Payment Terms: T/T, Western Union
Supply Ability: 500,000 tests per week
Contact Now
Detailed Product Description
Method: Latex Immunochromatography Specimen: Saliva
Fast: Get Result In 15 Minutes Rapid Test: No Instrument Use
High Accuracy: 98.0% Certificates: CE Mark, PEI Approval
Storage: 2-30℃ Valid: 18 Months
High Light:

Covid 19 Saliva Antigen Rapid Test Kit

,

Sars-Cov-2 Antigen Assay Kit

,

Latex Immunochromatography Saliva Swab Kit

Covid19 home test antigen kits saliva type CE mark

 

 

Product name Specimen Package  Components
Sars-Cov-2 antigen assay kit saliva 1/5/25test/kit
test card, sample
preservation solution , dripper and saliva collector.

 

The Diacegene Sars-Cov-2 antigen assay kit is intended for qualitative detection of Sars-Cov-2 N-protein antigen in human saliva samples. 

 

This product can be used as a supplementary test indicator for suspected cases with negative nucleic acid test of Sars-Cov-2 or uased in conjuction with nuckeic acid testing in diagnosis of suspected cases. 

 

Operation steps

Covid 19 Saliva Antigen Rapid Test Kit Sars-Cov-2 Saliva Swab Kit 0

Result interpretation
POSITIVE:  
Two red lines appear. One red line appears in the control region(C), and one red line in the test region(T). The shade of color may vary,but it should be considered positive whenever there is even a faint line.
NEGATIVE: 
Only one red line appears in the control region(C), and no line in the test region(T). The negative result indicates that there are no Novel coroinavirus particles in the sample or the number of viral particles is below the detectable range.
INVALID:
No red line appears in the control region(C). The test is invalid even if there is a line on test region(T).
Note 1: Insufficient sample volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the test procedure and repeat the test using a new test device. If the problem persists, discontinue using the test kit immediately and
contact your local distributor.
Note 2:The test results of this kit are only for clinicians' reference. The clinical management of patients should be comprehensively considered in combination with their symptoms / signs, medical history, other laboratory tests and treatment reactions.
Waste disposal
All samples and used accessories should be treated as infectious and discarded according to local regulations.
 

Contact Details
Sichuan Xincheng Biological Co., Ltd.

Contact Person: Poni Yin

Tel: +8615928809061

Send your inquiry directly to us
Best Products
Other Products