Self Testing Nasopharynx Saliva Antigen Rapid Test Kit With 1Pcs / Box

Self Testing Nasopharynx Saliva Antigen Rapid Test Kit With 1Pcs / Box

  • Self Testing Nasopharynx Saliva Antigen Rapid Test Kit With 1Pcs / Box
  • Self Testing Nasopharynx Saliva Antigen Rapid Test Kit With 1Pcs / Box
Self Testing Nasopharynx Saliva Antigen Rapid Test Kit With 1Pcs / Box
Product Details:
Place of Origin: China
Brand Name: Diacegene
Certification: CE, ISO13485, ISO9001, FSC
Model Number: T4103W
Payment & Shipping Terms:
Minimum Order Quantity: 1000 tests
Packaging Details: 1test,5tests,25tests/package
Delivery Time: 3-10 days
Payment Terms: T/T, Western Union
Supply Ability: 500,000 tests per week
Contact Now
Detailed Product Description
Method: Latex Immunochromatography Components: Test Card, Sample Preservation Solution , Dripper And Saliva Collector
Storage Temperature: 2-30 ℃ Validity Period: 18 Months
Testing Time: Within 15-20 Minutes Clinical Sensitivity: 96.0%
Clinical Specificity: 100% Specimen: Saliva
High Light:

1Pcs / Box Saliva Antigen Rapid Test Kit

,

Self Testing Saliva Antigen Rapid Kit

,

Nasopharynx Saliva Rapid Test Kit

Self testing Saliva Antigen Rapid Test Kit Rapid with 1 Pcs/Box

 

Cat.No Specifications test card sample processing fuild saliva collector
T4101W
1 test
1
1 1
T4102W
5 test 5 5 5
T4103W
25 test 25 25 25

 

Storage and stability
 
When the Sars-Cov-2 antigen rapid detection kit is placed at room temperature or refrigerated (2-30 ℃), the validity period of the product is 18 months. Don't freeze.
 
POSITIVE:
 
Two red lines appear. One red line appears in the control region(C), and one red line in the test region(T). The shade of color may vary,but it
should be considered positive whenever there is even a faint line.
NEGATIVE:
 
Only one red line appears in the control region(C), and no line in the test region(T).The negative result indicates that there are noNovel coroinavirus particles in the sample or the number of viral particles is below the detectable range.
 
INVALID:
 
No red line appears in the control region(C). The test is invalid even if there is a line on test
region(T).
Note 1: Insufficient sample volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the test procedure and repeat the test using a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Note 2:The test results of this kit are only for clinicians' reference. The clinical management of patients should be comprehensively considered in combination with their symptoms / signs, medical history, other laboratory tests and treatment reactions.
 